Ventilator Machine Price ICU trolley Medical ventilator Equipment
The PA700B ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.
Display: 10.4''LCD Display Following Parameters & Real time waveform display
Operating mode and respiratory rate;
——Ventilator control frequency set by medical staff;
——Tidal volume of each breath in the patient;
——Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
——Expiratory phase and inspiratory phase and actual respiratory rate;
Ventilator Construction:
--Environmental Protection Material construction, hardly to be broken.
-- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
TECHNIQUES SPECIFICATIONS | |||
Physical specifications | |||
Display | 10.4'' LCD Display | ||
Mode: | pneumatically powered and electrically controlled system | ||
Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions | ||
Technical Specifications: | |||
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa | ||
safety valve | <12.5 kPa | ||
Respiratory Rate | 1 ~ 99 bpm | ||
Oxygen concentration output | 21% ~ 100% adjustable | ||
Maximum Minute ventilation | ≥18L / min | ||
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT | ||
Ventilator compliance | ≤30 Ml/kPa | ||
PEEP: | 0 ~ 1.0 kPa | ||
Ptr: | -10 ~ 10 hPa | ||
IMV frequency: | 1~20 bpm | ||
I/E Ratio: | 4:1~1:4, Has the inverse ratio ventilation | ||
Tidal Volume | Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml | ||
Inspiratory Plateau: | 0~1s | ||
Maximum Safety Pressure | ≤ 6.0kPa | ||
Sigh: | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point | ||
Pressure limit range: | 1.0~ 6.0kPa | ||
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa | ||
±0.2 kPa | |||
Ventilation Volume alarm: | ≥ 18L/ MIN | ||
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s | ||
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure AC / DC Respiratory Machine Breathing , Ventilator Machine ICU Medical Equipment |